Assessment of an alternative method of measuring asbestos fibres in air

Measuring levels of asbestos in air is an important part of assessing the risk posed by work activities involving asbestos-containing materials. Asbestos causes around 5000 deaths in Great Britain every year and remains a problem because it can be present in any building built or refurbished before the year 2000.

The current HSE approved method for analysing asbestos fibre levels in air uses phase contrast microscopy (PCM) to count all fibres. One disadvantage of this method is that it does not discriminate between asbestos and non-asbestos fibres; discrimination is usually done using electron microscopy, a more costly and time-consuming analytical procedure.

A method developed by Japanese researchers offers the potential for simple discrimination between asbestos and non-asbestos fibres. HSE researchers have carried out testing of this method using commercially available testing kits.

The use of fluorescence as outlined by the Japanese researchers could lead to a method for discrimination that would act as a simple add-on to the current method. This could make analysis for asbestos fibres much quicker and cheaper.

When HSE scientists carried out testing of the commercially available analysis kits, all non-asbestos fibres used in the testing (wollastonite, refractory ceramic fibres, rock wool and man-made vitreous fibres) showed a level of fluorescence.

However the kits did not demonstrate that they could be used to effectively distinguish between asbestos and non-asbestos fibres.

You can view the orginal 2016 study here: Differential Counting of Asbestos Using Phase Contrast and Fluorescence Microscopy.